Immediate learning effect:
If the catheter is positioned correctly, fluid emerges exactly as it does with a real patient. In addition, the catheter position can be checked through the transparent bladder. The abdominal wall on the PRO version can be removed so that the procedure during urethral catheterisation can be better visualised.
Replacement and care of a suprapubic bladder catheter:
If catheterisation via the urethra is no longer possible, a suprapubic catheter must be inserted. The suprapubic catheter is usually placed by a physician through the abdominal wall into the filled urinary bladder and fixed to the abdominal wall. On the PRO version, replacement of the suprapubic catheter as well as its care can be practised. Care includes dressing changes, cleaning the catheter and disinfecting the wound.
All advantages of the female P93 PRO catheterisation simulator at a glance:
- Female catheterisation with realistic resistance
- Soft and movable labia (for practising e.g. disinfection)
- Anatomically realistic pelvic structure
- Fluid outflow after successful catheterisation
- Inspection option via the transparent bladder and
removable abdominal wall
- Training in suprapubic catheter replacement as well as its cleaning and care
- Stable on the table thanks to anti-slip feet
- Magnetic connections for quick set-up and conversion
- Easy to clean and maintain, can be completely disassembled
- Sponge inside prevents the build-up of moisture
Scope of delivery:
- Realistic lower abdomen model
- Female catheterisation insert with transparent bladder
- Bottle and tubing connections
- Carry bag
Note:
For catheterisation we recommend using catheters with only one or two opposing drainage eyes. Both silicone and PVC catheters can be used.
We recommend the following catheters:
Urethral narrowing “Open” = 16 CH catheter or 14 CH Foley catheter
Urethral narrowing “Partial narrowing” = 14 CH catheter or 12 CH Foley catheter
Catheters with a curved tip should not be used!
Tip:
In accordance with the guidelines for correct catheterisation, even in simulation a small amount of lubricating gel (not included) should be introduced into the urethra or into the puncture site on the abdominal wall to ensure smooth insertion of the catheter. Alternatively, the lubricating gel can also be applied to the tip of the catheter.